Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
1.
Sci Rep ; 13(1): 305, 2023 01 06.
Article in English | MEDLINE | ID: covidwho-2186077

ABSTRACT

A rapid and sensitive isocratic ion-pair chromatographic method was developed for the accurate analysis of ternary mixtures of formoterol, tiotropium, and ciclesonide in their novel combined inhalation that is widely used for the symptomatic treatment of patients with chronic obstructive disease. Analytical separation was performed using a C8 column and ion pair mobile phase composed of acetonitrile: acidified deionized water (55: 45% v/v) containing 0.025% sodium dodecyl sulfate. The pH was adjusted to 3.0 using orthophosphoric acid and eluted isocratically at 2.0 mL/min and 40 °C applying UV detection at 237 nm. The calibration ranges were found to be 0.3-9.0 µg/mL for formoterol, 0.45-13.5 µg/mL for tiotropium, and 10.0-300.0 µg/mL concerning ciclesonide. The proposed method exhibited good repeatability, accuracy, and sensitivity (R.S.D. < 2.0%). The approach is rapid (run time does not exceed 15 min) and achieves satisfactory resolution (resolution factors = 7.45 and 5.3 between formoterol and tiotropium and tiotropium and ciclesonide respectively). The sensitivity and the efficiency of the proposed method permit their successful estimation with a recovery percentage ± SD of 99.33% ± 0.43 for formoterol, 99.15% ± 0.60 for tiotropium, and 99.90% ± 0.41 for ciclesonide.


Subject(s)
Coronavirus Infections , Coronavirus , Humans , Tiotropium Bromide , Formoterol Fumarate , Chromatography, High Pressure Liquid/methods , Respiratory Therapy
2.
Respir Investig ; 59(6): 871-875, 2021 Nov.
Article in English | MEDLINE | ID: covidwho-1364443

ABSTRACT

Spirometry is a crucial test used in the diagnosis and monitoring of patients with chronic obstructive pulmonary disease (COPD). Severe acute respiratory syndrome coronavirus 2 pandemic has posed numerous challenges in performing spirometry. Dynamic-ventilatory digital radiography (DR) provides sequential chest radiography images during respiration with lower doses of radiation than conventional X-ray fluoroscopy and computed tomography. Recent studies revealed that parameters obtained from dynamic DR are promising for evaluating pulmonary function of COPD patients. We report two cases of COPD evaluated by dynamic-ventilatory DR for pulmonary function and treatment efficacy and discuss the potential of dynamic DR for evaluating COPD therapy.


Subject(s)
Lung/diagnostic imaging , Pulmonary Disease, Chronic Obstructive/diagnostic imaging , Radiographic Image Enhancement/methods , Radiography, Thoracic/methods , Aged , Asthma/diagnosis , Asthma/drug therapy , Bronchodilator Agents/therapeutic use , Drug Combinations , Fluticasone/therapeutic use , Formoterol Fumarate/therapeutic use , Glycopyrrolate/analogs & derivatives , Glycopyrrolate/therapeutic use , Humans , Indans/therapeutic use , Lung/physiology , Male , Middle Aged , Pulmonary Disease, Chronic Obstructive/drug therapy , Quinolones/therapeutic use , Spirometry , Tiotropium Bromide/therapeutic use , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL